Air Seeder Calibration Guide
Calibrating an air seeder is dull work, and it pays back every acre. A cart that is off by even a small percentage wastes seed or fertilizer across a whole field, or leaves a crop thinner than planned. The goal is simple: make the rate shown on the monitor match the pounds that actually leave the tank.
Before touching the meter
Start by cleaning out old product, since leftover seed and fertilizer change how the product flows. Check that the meter roller is the right one for what you are metering. Fine seeds like canola need a different roller than wheat, and the cart manual has a chart for roller choice. Confirm the roller and any gate settings are set as the chart says for the crop.
Look at the meter housing for worn or damaged flutes and cracked seals. A worn roller delivers inconsistently, and no amount of calibration fixes that.
The catch test
The usual method runs like this:
- Put the seed you will actually be planting in the tank. Treated seed and fertilizer flow differently than clean seed, so test with the real product.
- Position a catch container or bag under the meter outlet, as the manual shows.
- Enter the product, roller and target rate on the monitor and start the calibration routine.
- Crank the meter for the number of revolutions the cart tells you to, then weigh what you caught. Subtract the container weight.
- Enter the weight in the monitor. It works out a calibration number for that product.
Repeat the test at least twice. If the results disagree, find out why before you go on, because uneven flow means a plugged screen, a bridged tank or something loose.
Use an accurate scale. A bathroom scale that is off by a few ounces becomes a few pounds per acre across a field. Many operators run a second check with a known amount of product, and the check described in the planter seed metering calibration guide uses similar reasoning.
Fan speed and the field check
Air speed matters. Too slow and product settles in the hoses and plugs. Too fast and the seed bounces and cracks, particularly in the case of peas or other delicate seed. The manual lists a fan speed range for each crop and distribution setup. Watch the primary and secondary lines at first for even delivery.
The final test is in the field. Fill the tank to a known level, cover a measured number of acres, then see how much product went out. If the actual number differs from the monitor by a lot, repeat the calibration. Check the cart level and tank sensors too, since a cart inspection often turns up the odd leak in a hose or door seal that explains missing seed.
Recalibrate any time you switch product, roller, or seed lot, and after major repairs. Keep a notebook entry with the date, product and calibration number, since that saves time at the next change.
General information only. Follow the operator's manual and your dealer's service guidance for your specific machine.